Vue de la page 0
Onyx II
®
Model 9560 Bluetooth
®
Fingertip Oximeter
OEM Specification and Technical Information
NONIN
®
Medical, Inc.
13700 1st Avenue North
Plymouth, Minnesota 55441-5443
USA
763-553-9968
800-356-8874 (USA and Canada)
Fax 763-553-7807
E-mail: info@nonin.com
www.nonin.com
© 2008 NONIN
®
Medical, Inc.
6470-000-01
Vue de la page 0
1 2 3 4 5 6 ... 30 31

Résumé du contenu

Page 1 - Fingertip Oximeter

Onyx II® Model 9560 Bluetooth® Fingertip Oximeter OEM Specification and Technical Information NONIN® Medical, Inc. 13700 1st Avenue North P

Page 2

6 Data Packet Description The 9560 includes 6 bytes of header information, a minimum of 14 bytes of spot-check data, and 2 bytes of footer informa

Page 3 - Table of Contents

7 Data Format #13 Data Packet Description (continued) Status (MSB) BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0 R R R R R R SPA NOM

Page 4

8 Serial Date Format #2: This data format provides continuous data transmission of a 5 byte data packet sent 75 times per second. The data packet

Page 5 - Onyx II Model 9560 Bluetooth

9 Byte 1 – START BYTE: Always set to a 01 value. Byte 2 – STATUS BYTE This byte provides status information at a rate of 1/75th of second. R

Page 6 - Bluetooth Information

10 Byte 4 – FLOAT BYTE This byte is used for SpO2, Pulse Rate, and information that can be processed at a rate of 1/3 of second. Range: 00 to 12

Page 7 - Communications Interface

11 HR Format: 7 6 5 4 3 2 1 0 HR MSB 0 R R R R R HR8 HR7 7 6 5 4 3 2 1 0 HR LSB 0 HR6 HR5 HR4 HR3 HR2 HR1 HR

Page 8 - Setting the Time:

12 Serial Data Format #7: This data format provides the same information as Data Format 2, except that the waveform value provides the full resolu

Page 9

13 Byte 1 – STATUS BYTE This byte provides status information at a rate of 1/75th of a second. Range: 128 to 255 Byte 1 - Status BIT7 BIT6

Page 10 - Data Packet Description

14 Byte 4 – FLOAT BYTE This byte is used for SpO2, Pulse Rate, and information that can be processed at a rate of 1/3 of second. Range: 00 to 1

Page 11 - Data Format #13

15 Formatted for Display Purposes: These values are formatted for display purposes every 1.5 seconds. They provide the most reliable reading p

Page 13

16 Serial Data Format #8 This data format provides continuous data transmission of a 4 byte data packet sent once per second. The data packet incl

Page 14 - Byte 4 – FLOAT BYTE

17 The SpO2 and Pulse Rate values are formatted for display purposes every 1.5 seconds. They provide the most reliable reading possible durin

Page 15

18 Indications for Use The NONIN® Model 9560 Finger Pulse Oximeter is a small, lightweight, portable, wireless device indicated for use in measuri

Page 16 - Serial Data Format #7:

19 Cautions  artificial nails or fingernail polish The device may not work when circulation is reduced. Warm or rub the finger, or re-posit

Page 17

20 Regulatory Information Declaration of Conformity with FCC and Canadian Ministry of Health Rules for Electromagnetic Compatibility  Nonin Medi

Page 18

21 Using the Model 9560 Guide to Symbols on the Module Consult Instructions for Use. Caution! Type BF Applied Part (Patient isolation from

Page 19

22 4. Carefully guide the battery cover back onto the Model 9560, pressing downward and pushing inward slightly to re-secure the battery cover.

Page 20 - Serial Data Format #8

23 Model 9560 Care, Maintenance, and Cleaning The advanced digital circuitry within the Model 9560 requires no calibration or periodic mainten

Page 21

24 Manufacturer’s Declaration See the following tables for specific information regarding this module’s compliance to IEC 60601-1-2:2001. Table 1

Page 22 - Indications for Use

25 Table 3: Guidance and Manufacturer’s Declaration—Electromagnetic Immunity Immunity Test IEC 60601 Test Level Compliance Level Electromagnet

Page 23 - Cautions

i Table of Contents NONIN® Onyx II Model 9560 Bluetooth® Fingertip Oximeter Technology Specifications ... 1 Input/Output For

Page 24 - Regulatory Information

26 Table 4: Recommended Separation Distances The following table describes the recommended separation distances between portable and mobile RF com

Page 25 - Using the Model 9560

27 Testing Summary SpO2 accuracy, motion and low perfusion testing was conducted by NONIN® Medical, Incorporated as described below. SpO2 Accu

Page 27

1 NONIN® Onyx II Model 9560 Bluetooth® Fingertip Oximeter Technology Specifications 1. Oxygen Saturation Range (SpO2) 0 to 100% 2. Pulse R

Page 28 - Manufacturer’s Declaration

2 13. Bluetooth Information Bluetooth Compliance: Operating Frequency: Output Power: Operating Range: Network Topology:

Page 29

3 Input/Output Formatting Options Data Format Solutions The 9560 features four data format solutions. They are:  Data format 13 – provides e

Page 30

4 Selecting the Data Format To select the data format the host must send the 9560 the following 6 byte command string: Byte 1 Byte2 Byte3 B

Page 31 - Testing Summary

5 Retrieving Time from the 9560 To retrieve the time from the 9560, the host must send a 4 byte command string. Response: The 9560 sends

Commentaires sur ces manuels

Pas de commentaire